6000W Liquid cold plate thermal solution
Experise
Customized 6000W cold plate case sharing
LD Power :10*540W=5400W;
Optical Fiber Power: 1080W;
Al6063-T5 Material
Liquid cold plate with Extrusion process
Input flow rate 0.008m³/min ( 0.48m³/h)/8L/Min
Environment 25℃
Liquid cold plate surface Max temperature is below 35 ℃
Extracted water channel model in SCDM software
The number of meshes is 568804
Set uniform mesh params Mesh
assemblies separately
Allow multi-level meshing
Allow minimum gap changes
Set uniform mesh params Mesh
assemblies separately
Allow multi-level meshing
Allow minimum gap changes